LEONARD SS-7600 SURFASHOWER VALVE PARTS

Leonard Parts Troubleshooting Chart
DESCRIPTION: SYMPTOM: KIT REQUIRED:
PACKINGS & GASKETS 1. Leak at handle or cover.
2. Valve will not shut off completely.
KIT 1/7600
Cover o’ring
(2) Lower o’rings
Shuttle o’ring
Spring washer
Shut off gasket
COVER ASSEMBLY 3. After packings and gaskets have been replaced, valve will not shut off completely.
4. Valve does not respond when handle is turned
KIT R/7954
or Complete Rebuild
KIT R/SS7600
Complete cover assembly
SHUTTLE ASSEMBLY 5. After replacing packings and gaskets, valve will not hold temperature or delivers full hot or fullcold. KIT R/7931
or Complete Rebuild
KIT R/SS7600
Shuttle, wax element and spring
CHECKSTOPS, STOPS 6. Supplies cannot be shut off completely.
7. Leak at checkstops (or stop) bonnet or stem.
8. Hot water is crossing into cold or vise versa.
KIT 4/7600 (2 h) MU-6A,
7972,
MU-5A,
LVC-8A,

Refer to the Operational and Maintenance guide for full Troubleshooting Instructions.