LEONARD PAM-II-ST SERIES PG & SERIES N PARTS

Leonard Parts Troubleshooting Chart
SYMPTOM: KIT REQUIRED: PARTS INCLUDED:
PACKINGS & O-RINGS 1. Leak at handle.
2. Valve will not shut off completely.
3. Valve is difficult to pull apart.
4. Leak at stop screw.
KIT REQUIRED:
Kit 1/ST/N
PARTS INCLUDED:
PV-2, PV-4B, PV-8-1, LVC-16B, 1358, 1356, PV-16
CONTROL ROD GROUP 5. Valve delivers either all hot or all cold water or will not mix consistently Kit R/67 1358, PV-CR-2, PV-3, PV-16 (2)
INSERTED SEAT 6. After replacing packings and O-rings, valve will not shut off completely. PV-3, PV-16 (2) (also PV-45 if hex tool not available).
CHECKSTOPS 7. Supplies cannot be shut off completely.
8. Leak at checkstop (or stop) bonnetor stem
KIT 4/LVC
(F checkstops)
KIT"B"
(SB,TB checkstops) KIT "C"
(S stops)

Refer to the Operational and Maintenance guide for full Troubleshooting Instructions.