LEONARD M-15-C, M-15-E, M-20-C, M-20-E CHECKSTOPS
2 EACH REQUIRED - SOLD SEPERATELYDESCRIPTION: | SYMPTOM: | KIT REQUIRED: |
PACKINGS & GASKETS | 1. Leak at handle. 2. Leaks between valve cover and base. 3. Volume control will not shut off completely | Kit 1/M20 includes 1 M20-3C, 1 M20-3E, 2 M20-3A, 2 M20-6B, 1 M20-6E, 2 M20-5A, 2 MU-4C, 1 M20-10E, 2 M20-9A, |
PORT SLEEVE ASSEMBLY | 4. Valve delivers either all hot or all cold water or will not mix consistently. Clean or replace port sleeve assembly | Kit 2/M20 includes: 2 M20-3B, M20-6B, 1 M20-G1, M20-14B |
THERMOSTAT GROUP | 5. After replacing port sleeve assembly, valve will not hold temperature. Clean or replace thermostat group | ALTERNATE: ORDER 1 M20-1-8B, OR KIT R/M20, KIT R/M20, OR 1 M20-G2, |
CHECKSTOPS | 6. Hot water by-passes into cold line (or cold into hot). 7. Supplies cannot be shut off completely. | Kit 4/M20 includes: 2 M20-3A, 2 M20-5A, 2 M20-6A, 2 M20-9A |
Refer to the Operational and Maintenance guide for full Troubleshooting Instructions.